JAX Air Conditioner Error Codes

Fault identification by digital codes

E2

 Internal air temperature sensor shorted or closed

 E3

 Evaporator temperature sensor closed or broken

 E4

 Condenser temperature sensor shorted or closed

 E5

 Drain pump error (engine overheated)

 E6

 Protection of the external unit (rephasing, phase failure, thermal protection)

 E7

 EEPROM Error

 E8

 Drain pan overflow protection (more than 3 minutes)

Flashing indicators on the indoor unit panel

Flashing indicators

 Malfunction

 Note

 operation+timer+def/fan

 Compressor current overload detected, more than 4 times in one hour

 Error reset by turning off the power

 water alarm LED (blinks)

 The float recorded an increase in the level of condensate in the pan, no more than three minutes

 Forcedly turns on a drainage pump 

 water alarm LED (lit)

 Drain float does not lower for more than 3 minutes

 The air conditioner is in an accident, reset by turning off the power

  def/fan (pre/def)

  Condenser temperature sensor closed or broken

When the cause is eliminated, the air conditioner automatically resumes operation

 all indicators blink

  External unit error - phase failure or rephasing, thermal protection

 

 timer

  Broken or shorted indoor temperature sensor

 

  operation

  Evaporator Temperature Sensor Error - Closed or Broken

 

operation+timer

  EEPROM Error

 Change control board

Knowing the error codes, it is easy to repair the air conditioner, including JAX.

 

They can significantly reduce the time of diagnosis and more accurately identify the cause of the breakdown.

JAX Air Conditioner Error Codes
Jax ACI-10HE frankly
Comments: 0