Chigo Air Conditioners Error Codes

Modern CHIGO air conditioners have a developed self-diagnosis system, according to the results of which the control system, upon detection of a malfunction, blocks the operation of the entire device and at the same time reports the cause of the malfunction.

 

The CHIGO air conditioning control system reports any malfunctions by flashing the LED on the panel of the indoor unit. If one or another malfunction of the air conditioner is detected, the LEDs light or flash in a certain sequence, which corresponds to the detected error. If the control system of the air conditioner has detected more than one error, then the fault with the highest priority is displayed first, and then all the others.

 

 

The codes of malfunctions (errors) of CHIGO air conditioners are given in the table:

Error codes for wall split systems

Problems

Display

Display

LCD

Indoor unit

RUNNING LAMP

TAMER LAMP

 

Room temperature sensor

blinks 1 \ lights 8 sec

glows

E2

Evaporator Temperature Sensor

blinks 2 \ lights 8 sec

glows

E3

Air conditioner overheating

blinks 3 \ lights 8 sec

glows

E8

Pump (Overflow)

blinks 4 \ lights 8 sec

glows

E9

Fan motor

blinks 6 \ lights 8 sec

glows

E5

No communication with external unit

7 blinks / 8s

glows

E7

Lid not closed

glows

blinks 3 \ lights 8 sec

E0

Condenser temperature sensor

glows

blinks 4 \ lights 8 sec

E1

EEPROM does not work

glows

blinks 6 \ lights 8 sec

E6

For three-phase systems

Problems

Display

Display

LCD

External Block

RUNNING LAMP

TAMER LAMP

 

Outdoor temperature sensor

glows

blinks 1 \ lights 8 sec

E2

Pipe temperature sensor

glows

blinks 2 \ lights 8 sec

E3

Compressor overheating

glows

blinks 3 \ lights 8 sec

E7

 

glows

blinks 4 \ lights 8 sec

E1

No inter-unit communication

glows

blinks 6 \ lights 8 sec

E6

 

glows

7 blinks / 8s

E5

Indication of malfunctions of cassette conditioners

Error decoding

Indication

Defrost

blinks 1 time \ does not light up 1 second.

Frost protection

flashes  1 time \ does not light for 3 seconds.

Room temperature sensor

blinks  2 times \ does not glow for 4 seconds.

Pipe temperature sensor

flashes  3 times \ does not light up for 5 seconds.

Error from external unit

blinks  4 times \ does not light up for 6 seconds.

Block frost protection

blinks  5 times \ does not light up for 7 seconds.

Low pressure protection

blinks  6 times \ does not light up for 8 seconds.

Power Protection for External Unit

blinks  7 times \ does not light up for 9 seconds.

overheat protection

blinks  8 times \ does not light up 10 seconds.

Condensation overflow protection

flashes  9 times \ does not light for 11 seconds.

Indication of malfunctions of ducted air conditioners

Malfunction

Alarm Code

 

E1

abnormal sensor temperature

E2

Room temperature sensor

E3

Error from external unit

E4

No inter-unit communication

E7

Overheat / frost protection

E8

 

E9

Chigo: Error codes for columned air conditioners

 

Malfunction

Display

No inter-unit communication

E1

Room air temperature sensor

E2

Evaporator Temperature Sensor

E3

Low pressure protection

E4

Phasing error

E7

overheat protection

E8

Error from external unit

E9

Chigo: Fault codes for subceiling split systems

Malfunctions

Indication

Defrost mode

blinks 1 time \ does not light up 1 second.

Frost protection

blinks 1 time; does not light for 3 seconds.

Room temperature sensor

2 times blinks \ do not glow for 4 seconds.

Evaporator Temperature Sensor

3 times blinks / do not glow for 5 seconds.

Outdoor unit error

4 times blinks \ do not glow for 6 seconds.

Anti-freeze protection of indoor unit

blinks 5 times \ does not glow for 7 seconds.

Low Pressure Error

blinks 6 times \ does not glow for 8 seconds.

External unit power failure

blinks 7 times \ does not glow for 9 seconds.

overheat protection

blinks 8 times \ does not glow for 10 seconds.

Condensate overflow accident

blinks 9 times / does not light for 11 seconds.

Chigo: CMD intelligent vulti connected series

Malfunctions

Indication

Internal air temperature sensor

E2

Evaporator Temperature Sensor

E3

Error from external unit

E4

Fan motor failure

E5

Defrost mode

E6

Chigo Air Conditioners Error Codes list
Comments: 11
  • #11

    NISHAN (Thursday, 20 April 2023 10:46)

    H 4 ERROR CODE

  • #10

    faru@bellsouth.net (Monday, 17 April 2023 20:03)

    My Chigo a/c is on F5 and F7 errors, do I need to replace the electronic circuit to fix it, can you help me to locate a vendor

  • #9

    Andrew (Friday, 07 October 2022 00:34)

    Chico air conditioner 7.5kW.
    FF fault.
    Refrigerant is fine-not short, no blockage.
    4wayvalve is fine
    Pcb is fine.
    WHAT OTHER ISSUES CAN FF FAULT REFER TO.
    100 chigos purchased and about half have ff fault come up

  • #8

    Tory Meyers (Wednesday, 12 January 2022 21:30)

    My Chigo mini split keeps frosting over. I have had a HVAC person come by and check for Freon leaks and recharge the unit. It currently was working fine but is now frosted over again. I have noticed the heat indicator light keeps blinking where the fan turns off and on blowing warm air. I assume this is from it being frosted over. Any ideas on why this is happening. It goes into defrost mode but seems not to work

  • #7

    Marius may (Thursday, 09 December 2021 13:19)

    I would like to know what does it mean when a cassette type r22 aircon flashes defrost continuesly model CCA-24H

  • #6

    Robert Lininger (Friday, 05 November 2021 14:21)

    I have a split unit. The indoor unit blinks once every 1-2 seconds. I have no error code on my remote. What could the problem be

  • #5

    Robert Lininger (Friday, 05 November 2021 13:59)

    I have a split unit. The indoor unit blinks once every 1-2 seconds. I have no error code on my remote. What could the problem be

  • #4

    Robert Lininger (Friday, 05 November 2021 13:58)

    I have a split unit. The indoor unit blinks once every 1-2 seconds. I have no error code on my remote. What could the problem be

  • #3

    Jannie Meyer (Wednesday, 09 June 2021 09:49)

    My power indicator light on the internal unit flashes, what does this mean?

  • #2

    hk2chimbala@gmail.com (Thursday, 22 October 2020 17:26)

    Indoor working perfect later display reads F1
    compressor not running not even harming
    What is the solution

  • #1

    Ken Esposito (Tuesday, 28 July 2020 18:01)

    Light is blinking 4 times on indoor split unit. Its 90 ° outside with high humidity. Do I need freon recharge?